GE 118 Corometrics fetal Monitor

    GE 118 Corometrics fetal Monitor

    $0.00
    DESCRIPTION

    The Corometrics 118 Fetal Monitor is a twin capable unit that includes one toco and two ultrasound transducers, fetal EKG, event marker and a chart recorder. Data storage and transmission Integrated Maternal Pulse Oximetry NIBP. Extends upon the advanced technology of the Model 116 with integrated maternal pulse oximetry and/or noninvasive blood pressure monitoring.

    Features
    Easy operation
    Intuitive controls and menus
    Simplified operation of all functions
    Controls are tailored for labor and delivery to make operation user friendly
    Visual/Audible Maternal Alarms
    The unit provides visual and audible alarms when maternal SpO2, NIBP or pulse rate values exceed user-defined high/low limits
    Audible alarms can be disabled
    Individual audio/visual alarms can be temporarily canceled
    SPECIFICATIONS
    Physical Weight & Dimensions
    Height: 7 inches (17.8 cm)
    Width: 16.5 inches (41.9 cm)
    Depth: 17 inches (43.2 cm)
    Weight: Approx. 34 lbs (15.5 kg)
    Power Requirements
    Voltage: 100/120/220/240 VAC selectable
    Frequency: 50/60 Hz.
    Power consumption: 100 Watts (max)
    Direct ECG
    Technique: peak detecting beat-to-beat cardiotachometer.
    Heart rate counting range: 30-240 BPM.
    Heart rate resolution: ±1 BPM.
    Artifact elimination: switch selectable±25 BPM artifact rejection.
    Input signal range differential: 15 µV to 2 mV peak-to-peak (fetal), 100 µV to 2 mV peak-to-peak (maternal).
    Common mode: 20 VDC (max.).
    Preamplifier bandwidth: 1.0 Hz to 100 Hz.
    Common mode rejection: >120 dB balance. With patient cable: >110 dB 5k RA or LA unbalance.
    Input equivalent noise: < 10 µV peak-to-peak.
    Input impendence: differential mode > 10 M?, common mode > 20 M?.
    Main frequency rejection: >40 dB.
    Leakage current: < 10 µA at 120 VAC.
    Isolation mains to patient connection: >2kV.
    Leg plate tester: simulated r-wave at 120 ±1 BPM.
    Ultrasound
    Technique: pulsed doppler with autocorrelation processing.
    Pulse repetition frequency: 4kHz in single ultrasound mode, 2 kHz in dual ultrasound mode.
    Pulse duration: 92µs.
    Center frequency: 1.151 MHz
    Intensity: <10 mW/cm2
    Heart rate counting range: 50-210 BPM.
    Leakage current: <10 µA at 120 VAC.
    Pressure
    Range: 0-100 mmHg
    Tocotransducer: 0-100 relative units (0-120 grams)
    Excitation voltage: +4.0 VDC
    Resolution: 1 mmHg
    Bandwidth: tocotransducer DC to 0.5 Hz, strain gauge DC to 3 Hz
    Zero temperature drift: < 0.1 mmHg/°C (electronics only).
    Leakage current: <10 µA at 120 VAC (transducer isolated).
    Recorder
    Uterine activity: chart width: 4 cm, scaling: 25 mmHg/cm (3.33 kPa/cm), range: 0-100 mmHg, resolution: 1 mmHg.
    Chart drive: speeds: 1, 2 and 3 cm/min; accuracy: ±1%.
    Heart rate scale: domestic - chart width 7 cm, scaling 30 BPM/cm, range 30-240 BPM, resolution 1 BPM; international: chart width 8 cm, scaling 20 BPM/cm, range 50-210 BPM, resolution 1 BPM