Masimo Radical-7 Rainbow Monitor

    Masimo Radical-7 Rainbow Monitor

    $0.00
    DESCRIPTION

    Proven in more than 100 independent and objective studies to provide the most accurate and reliable SpO2 readings during motion and low perfusion.
    Upgradable Masimo Rainbow SET technology platform lets you add total hemoglobin and oxygen content through simple field-installed software upgrades.
    Additional upgrades allow you to continuously and non-invasively measure carboxyhemoglobin, methemoglobin and PVI.
    Linked to improved care and reduced medical errors.
    Enhanced probe-off detection with Rainbow sensors.
    Color display allows immediate differentiation of critical measurements.
    FEATURES:

    Clinically proven to be the highest sensitivity and specificity pulse oximeter in the world
    Masimo Rainbow SET technology uses multiple wavelengths of light to continuously and noninvasively measure hemoglobin, Oxygen Content, carboxyhemoglobin and methemoglobin, as well as providing the most reliable probe-off detection.
    Perfusion Index with trending capability indicates arterial pulse signal strength and may be used as a diagnostic tool during low perfusion
    Pleth Variability Index: captures vital thoracic pressure changes that may compromise normal cardiac function affecting systemic circulation
    Accurate on cyanotic patients
    Signal IQ waveform for signal identification and quality indication during excessive motion and low signal to noise situations
    FastSat tracks rapid changes in arterial O2 with high fidelity unlike any other pulse oximeter
    Variable pitch provides tonal variance for every 1% change in saturation
    SatShare interface allows transfer of SpO2 and pulse rate to existing multiparameter monitor and allows for the reading of SpCO and SpMet on adjacent Radical-7 monitor
    Automatic screen rotation provides upright display for vertical or horizontal monitor positioning (not available on the RDS-2 model)
    Remote alarming interface
    Up to eighteen days of trending
    Detachable portable hand-held for patient transport
    3D Alarm System Option

    Desat Index Alarm enables clinicians to detect an increasing quantity of smaller desaturations that may precede declining respiratory status
    PI Delta Alarm™ alerts clinicians to specified changes in perfusion, often a reliable indicator of illness severity
    SIGNAL IQ

    As the plethysmograph waveform gets corrupted with motion, the Signal IQ indicator shows the location of the pulse, while the height of the vertical bar indicates the quality of the values displayed. When the signal quality is compromised during excessive motion, a “Low Signal IQ” message is displayed.

    Fast Trend

    Radical-7 Quick Trend feature allows for one-touch button access to parameter trending information with the ability to adjust the trending data for specific patient conditions.

    Automatic Display Rotation

    Automatic Display Rotation (Gravity Activated) Provides for vertical and horizontal positioning to maximize space utilization and visibility.

    Performance
    Measurement Range

    SpO2: 0 – 100%
    SpMet: 0 – 99.9%
    SpCO: 0 – 99%
    SpHb: 0 – 25 g/dL
    SpOC: 0 – 35ml of O2/dL of blood
    Pulse Rate: 25 – 240 bpm
    Perfusion Index: 0.02 – 20%
    PVI: 0 – 100%
    Oxygen Saturation Accuracy (%SpO2)

    Saturation: 60 – 80%
    No Motion
    - Adults/Infants/Pediatrics: ± 3%
    Saturation: 70 – 100%
    No Motion
    - Adults/Infants/Pediatrics/Neontates: ± 2%
    Motion
    - Adults/Infants/Pediatrics/Neonates: ± 3%
    Low Perfusion
    - Adults/Infants/Pediatrics/Neonates: ± 2%
    Pulse Rate Accuracy

    Pulse Rate: 25 – 240 bpm
    No Motion
    - Adults/Infants/Pediatrics/Neonates: ± 3 bpm
    Motion
    - Adults/Infants/Pediatrics/Neonates: ± 5 bpm
    Low Perfusion - Adults/Infants/Pediatrics/Neonates: ± 3 bpm
    Carboxyhemoglobin Saturation Accuracy (%SpCO)

    Adults/Infants/Pediatrics: 1 – 40% ± 3%
    Methemoglobin Saturation Accuracy (%SpMet)

    Adults/Infants/Pediatrics/Neonates: 1 – 15% ± 1%
    Total Hemoglobin Accuracy (SpHb g/dL)

    Adults/Infants/Pediatrics/Neonates: 8 – 17 g/dL + 1 g/dL
    Resolution

    Oxyhemoglobin Saturation (%SpO2): 1%
    Carboxyhemoglobin Saturation (%SpCO), digital display: 1%
    Methemoglobin Saturation (%SpMet), digital display: 0.1%
    Total Hemoglobin (SpHb g/dL): 0.1 g/dL
    Pulse Rate (bpm): 1 bpm
    Electrical
    Standalone

    AC power requirements: 100 – 240 VAC, 47 – 63 Hz
    Power consumption: 55 VA
    Fuses: 1 Amp, Fast Acting, Metric, (5x20mm), 250V
    Batteries
    Handheld

    Type: NiMH
    Capacity (battery life): 4 hours
    Charging time: 3 hours
    Standalone (Model RDS-18 Only)

    Type: NiMH
    Capacity (battery life): 10 hours
    Charging time: 8 hours
    Environmental
    Operating temperature: 41°F to 104°F (5°C to 40°C)
    Storage temperature: -40°F to 158°F (-40°C to + 70°C)
    Operating humidity: 5% to 95%, noncondensing
    Operating altitude: 500 mbar to 1060 mbar pressure
    -1000 ft to 18,000 ft (-304 m to 5,486 m)
    SPECIFICATIONS:
    Dimensions: 8.9” x 3.5” x 2.1” (22.6 cm x 8.9 cm x 5.3 cm)
    Standalone: 3.5” x 10.5” x 7.7” (8.9 cm x 26.7 cm x 19.6cm)
    Weight

    Handheld: 1.2 lbs (0.54 kg)
    Docking Station
    - Models RDS-1, 2, and 3: 2.5 lbs (1.14 kg)
    - Model RDS-1B: 3.1 lbs (1.41 kg)
    Standalone
    - Models RDS-1, 2, and 3: 3.7 lbs (1.68 kg)
    - Model RDS-1B: 4.3 lbs (1.95 kg)
    Trending
    Provides 72 hours of trending at 2-second resolution for >10 days at 10 second resolution of SpO2, SpHb, SpOC, SpMet, SpCO, Pulse Rate, and Perfusion Index with output to serial printer or other serial devices.

    SpO2 Modes

    Averaging mod: 2, 4, 8, 10, 12, 14, or 16 seconds
    Sensitivity.: Normal, APOD, and Maximum
    Alarms
    Audible and visual alarms for high low saturation and pulse rate (SpO2 range 1-99%, pulse rate range 30-235 bpm, SpCO 1-98%, SpMet .1-99.5%, SpHb 1-24.5 g/dl, PI .03-19%, PVI 1-99%)

    Display/Indicators

    Data display: %SpO2, %SpMet, %SpCO, SpHb, pulse rate, pleth waveform, alarm status, trends, status messages,Signal IQ, perfusion index, MAX and APOD sensitivities, PVI and FastSat
    Display Color: Multi-color or monochrome blue
    Type: TFT Color LCD
    Pixels: 480 x 272 dots
    Dot Pitch: 0.20 mm
    Output Interface
    SatShare (RDS-1, RDS-1B); Serial RS-232 (RDS-1, RDS-1B, RDS-3); Nurse Call/Analog Output (RDS-1, RDS-1B, RDS-3); Philips Vuelink, Spacelabs Universal Flexport, RadNet, Patient SafetyNet (RDS-1, RDS-1B, RDS-3)

    ADDITIONAL INFORMATION
    REVIEWS

    RECENTLY VIEWED PRODUCTS

    BACK TO TOP