No Products in the Cart
This kit includes:
SureBP Non-invasive Blood Pressure
SureTemp Plus Thermometer
Covidien SpO2
Designed with Patient Outcomes in Mind
Quickly and securely access a device with single sign-on (including Imprivata integration)
Measure blood pressure in just 15 seconds with SureBP technology
Help ensure accurate hypertension detection with BP averaging
Connect to your EMR with WiFi, Ethernet, Bluetooth or Bluetooth Low Energy
Enter height, weight and BMI with Scale-Tronix, Detecto, Health o meter or SECA scales
Help identify signs of patient deterioration with automated Early Warning Scores
Customize your workflow to document patient observations and vitals modifiers
Meet your workflow needs with mobile stands, wall mounts and integrated exam systems
Secure patient information with data encryption and additional security features specified by the U.S. Department of Defense (DoD)
welch-allyn-connex-graph.png
TECHNICAL INFO
NONINVASIVE BLOOD PRESSURE (NIBP)
Cuff Inflation Target Adult: 160 mmHg Pediatric: 140 mmHg Neonate: 90 mmHg
Systolic Range Adult/Pediatric: 30 – 260 mmHg Neonate: 20 – 120 mmHg
Diastolic Range Adult/Pediatric: 20 – 220 mmHg Neonate: 10 – 110 mmHg
MAP Range Adult/Pediatric: 23 – 230 mmHg Neonate: 13 – 110 mmHg
Blood Pressure Accuracy Meets the ANSI/AAMI SP10: 2002 and ISO/ANSI/AAMI 81060-2:2013 standards for noninvasive blood pressure accuracy (±5 mmHg mean error, 8 mmHg SD)
BP Determination Time: 15 seconds typical, 150 seconds max
Overpressure Cutoff Adult/Pediatric: 300 mmHg ± 15 mmHg Neonate: 150 mmHg maximum
Pulse Rate Range Adult/Pediatric: 30 – 200 bpm Neonate: 35 – 220 bpm
Pulse Rate Accuracy ± 5.0% (±3 bpm)
Temperature
Measurement Range SureTemp® Plus: 80 - 110°F (26.7 – 43.3°C) Braun: 68 - 108°F (20 – 42.2°C)
Calibration Accuracy SureTemp Plus: ±0.2°F (±0.1°C) Braun: ±0.4°F (for temps up to 107.6°F), ±0.5°F (for temps higher than 107.6°F)
Determination Time Oral: Approximately 4-6 seconds Adult Axillary (18 years and older): Approximately 15 seconds Pediatric Axillary (17 years and younger): Approximately 10 seconds Rectal: Approximately 10 seconds Tympanic: Approximately 3 seconds
SPO2
Measurement Range : 1-100%
Pulse Rate Range :Masimo: 25 – 240 bpm Nellcor: 25 – 240 bpm Nonin: 40 – 240 bpm
SpO2 Accuracy: Masimo: ± 2 digits Nellcor: ± 3 digits Nonin: ± 3 digits
Pulse Rate Accuracy: Masimo: ± 3 digits Nellcor: ± 3 digits Nonin: ± 3 digits
MECHANICAL
Dimensions: Height: 6.3 in (16.1 cm) Width: 9.2 in (23.4 cm) Depth: 2.3 in (5.8 cm)
Weight: 2.9 lbs (1.3 kg)
ENVIRONMENTAL
Operating Temperature: 50 – 104°F (10 – 40°C)
Storage Temperature:-4 – 122°F (-20 – 50°C)
Operating Altitude: -1250 – 10,000 ft. (-381 – 3,048 m)
Operating Humidity: 15% to 90% noncondensing
Storage Humidity: 15% to 95% noncondensing
EMC Standard: IEC/EN 60601-1-2
ELECTRICAL
AC Power Supply: 15V at 2.33A
Operating Time (Integrated 2-Cell Battery): Up to 12 hours with fully charged battery
Battery Recharge Time: 4 hours
Operating Time (APM with 9-Cell Battery): Up to 17 hours
WIRELESS RADIO
Wireless Network Interface: IEEE 802.11 a/b/g/n
Frequency: 2.4 GHz – 2.483 GHz (2.4 GHz bands) 5.15 GHz to 5.35 GHz, 5.725 GHz to 5.825 GHz (5 GHz bands)
Authentication/Encryption: Wireless Equivalent Privacy (WEP, RC4 Algorithm); Wi-Fi Protected Access (WPA); IEEE 802.11i (WPA2); TKIP, RC4 Algorithm; AES, Rijndael Algorithm; Encryption Key Provisioning; Static (40-bit and 128-bit lengths); PSK; Dynamic; EAP-FAST; EAP-TLS; EAP-TTLS; PEAP-GTC 1 PEAPMSCHAPv2; PEAP-TLS
FIPS 140-2: Yes
Device Data Security Features: FIPS-approved encryption algorithms of transmitted data; Server authentication of the device; Digitally signed software images and configuration files