No Products in the Cart
Reconditioned Verathon BladderScan BVI 9400 Features The Verathon BladderScan BVI 9400, available in a refurbished state, is a portable ultrasound device designed for measuring bladder volume in patients. Incorporating NeuralHarmonics technology, this bladder scanner swiftly generates a three-dimensional image of the patient's bladder. The Verathon BladderScanner is capable of calculating and displaying the bladder volume based on these images. The BVI is a compact, battery-operated console that offers diverse measurements while ensuring patient comfort. This ultrasound machine is accurate, reliable, and user-friendly, suitable for use across pediatric to adult patients. Key Features: 1. Precision aiming capability via console or probe. 2. Voice-annotate exams for the retention of valuable patient/exam data. 3. On-board printer for patient records or reimbursement procedures. 4. Easy viewing and saving of exams for creating Electronic Medical Records (EMRs). 5. Online calibration option. Verathon BladderScan 9400 Specifications Dimensions: - Height: 3 - 10.5" (7.62 - 26.67cm) - Width: 8.75" (22.23cm) - Depth: 12.5" (31.75cm) Weight (With battery): 5.2 lb (2.36kg) Standards: - International Electrotechnical Commission: EN/IEC 60601-1 Amendments 1 and 2 and EN/IEC 60601-1-2 (EMC) - Safety Standard: EN/IEC 60601-2 - Medical Device Directive: MDD 93/42/EEC Annex 1 - Canadian Standards Association: C22.2 No. 601.1-M90 (Master Contract No. 177198) - Underwriters Laboratories, Inc.: UL 60601-1 Display: - Height: 3.99" (10.13cm) - Width: 5.26" (13.36cm) - Resolution: 640 x 480, 120 dpi Instrument: - Input: Lithium-Ion Battery Pack. Verathon P/N 0400-0066 - Output: No load to full load at rated voltage. Refer to unit label - Insulation: The power supply is Class I with basic insulation to each terminal - Transient Overvoltage: Category II - Integrated printer: Thermal label printer Ultrasound Output Parameters: - Maximum ultrasound Ispta during a scan: ≤ 5.0 m W/cm2 - Maximum ultrasound Isppa during a scan: ≤ 60.0 W/cm2 - Maximum MI (Mechanical Index): .95 max - Transducer diameter: 13 mm (0.512 inches) - Transducer resonant frequency: 3.0 MHz and 1.74 MHz - Transducer bandwidth: 75% at 10 dB - Time from 3D scan initiation to result display: < 3 seconds - Penetration depth (in normal North American patient): ≥ 15 cm Accuracy: - Bladder volume accuracy: ± 15%, ± 15 ml (on a Verathon tissue-equivalent phantom) - Bladder volume range: 0 - 999 ml (0-200ml in small child scan mode) Operating Conditions: - Use: Indoor - Ambient Temperature Range: +10 - +40º Celsius (+50 - +104º Fahrenheit) - Atmospheric pressure range: 700 hPa - 1060 hPa - Relative humidity: 30% - 75% non-condensing - Water resistance: Rated at IPX1 (indicates DRIP-PROOF, a higher than ORDINARY level of protection from drips, leaks, and spills) Storage Conditions: - Storage: Indoor - Ambient Temperature Range: -20 - +60º Celsius (-4 - +140º Fahrenheit) - Atmospheric pressure range: 500 hPa - 1060 hPa - Relative humidity: 20% - 95% non-condensing Battery: - Battery type: Lithium Ion - Battery life: A fully charged battery can provide approximately 30 exams within a 24-hour period - Charging time: Charging time offline will take no more than six hours from an empty battery to a full charge - Rated Capacity: 5200 mAh - Normal Voltage: 10.89 V - Max Charging Voltage: 12.6 V - Max weight: 0.77 lbs (350 g) - Height: 0.91" (2.3 cm) - Width: 3.11" (7.9 cm) - Depth: 4.65" (11.8 cm) |