    GE Dash 5000 Key Features:
    The GE Dash 5000 is a versatile portable patient monitor equipped with a built-in writer and compatibility with the CARESCAPE network. It offers connectivity options through an optional wireless card or wired ethernet connection. This monitor unit is capable of monitoring ECG, NIBP, impedance respiration, SpO2, and temperature. Additionally, the Dash monitor can optionally monitor invasive pressure, BISx, and EtCO2.

    - Mainstream and low-flow sidestream CO2 measurement options for neonatal patients and adults.
    - Highly configurable with the ability to add features and parameters for different acuity levels.
    - Advanced algorithms for all parameters.
    - Features a 12.1-inch display.
    - Multiple mounting solutions available.
    - Wired or wireless ECG acquisition.

    GE Dash 5000 Specifications:
    Dimensions
    - Height: 11.3 in (28.7cm)
    - Width: 12.2 in (30.7 cm)
    - Depth: 9.4 in (23.9 cm)
    - Weight: 14 lbs. (6.4 kg)

    Battery
    - Type: Exchangeable Lithium-Ion
    - Number of Batteries: Up to 2
    - Weight: 0.8 lbs (0.36 kg) each
    - Voltage: 11.1 V (nominal)
    - Capacity: 3520 mAh
    - Charge Time: Less than 4 hours each
    - Run Time: 2.5 hours (5.0 hours with 2)

    Recorder
    - Method: Thermal dot array
    - Horizontal Resolution: 480 dots/in
    - Vertical Resolution: 200 dots/in
    - Waveform Channels: 4
    - Paper Width: 1.97 in (50 mm)
    - Paper Length: 100 ft (30 m)
    - Paper speed: 0.1, 0.5, 1, 5, 10, 12.5, 25, and 50 mm/sec

    Display
    - Size: 12.1 in diagonal
    - Type: Color LCD
    - Resolution: 800x600 pixels
    - Number of Traces: 6
    - Sweep Speed: 6.25, 12.5 or 25 mm/sec
    - Parameter Blocks Displayed: Up to 10

    Controls
    - Standard: Trim knob control plus 5 hard keys: Power, NBP Auto, Zero All, Silence Alarm/Admit, Print

    ECG
    - 5 Leadwire Cable: I, II, III, V, aVR, aVL, and aVF
    - 10 Leadwire Cable (12SL option): V2, V3, V4, V5 and V6
    - Voltage Range: ±0.5 mV to ±5 mV
    - Signal Width: 40 ms to 120 ms (Q to S)
    - Heart Rate Range: 30 to 300 BPM
    - Accuracy: ±1% or ±1BPM whichever is greater

    Invasive Blood Pressure (Optional)
    - Channels: 2
    - Transducer Sites: ART, FEM, PA, CVP, RA, LA, ICP, SP. In neonatal mode UCA, and UVC.
    - Range: -25 mmHg to 300 mmHg
    - Offset: ±150 mmHg

    Noninvasive Blood Pressure
    - Technique: Oscillometric
    - Displayed Parameters: Systolic, diastolic, and mean pressures, time of last measurement
    - Modes: Manual, auto, and stat in adult and OR modes; manual and auto in neonatal mode
    - Systolic Pressure Range: Adult: 30 to 285 mmHg; Pediatric: 30 to 235 mmHg; Neonatal: 30 to 140 mmHg
    - Diastolic Pressure Range: Adult: 10 to 220 mmHg; Pediatric: 10 to 210 mmHg; Neonatal: 10 to 110 mmHg
    - Mean Pressure Range: Adult: 20 to 260 mmHg; Pediatric: 20 to 220 mmHg; Neonatal: 20 to 125 mmHg
    - Cuff Pressure Range: Adult: 294 ± 6 mmHg; Pediatric: 250 ± 5 mmHg; Neonatal: 147 ± 3 mmHg
    - Heart Rate Detection: 30 to 200 beats per minute

    BIS - Bispectral Index
    - Technology: Supports Aspect Medical BIS-x technology
    - Information Displayed: BIS, SQI, SR and SEF, EEG waveform
    - BIS Range: 0-100
    - Signal Quality Index (SQI) Range: 0-100
    - Suppression Ratio (SR) Range: 0-100%
    - Spectral Edge Frequency (SEF) Range: 0-30
    - Alarms: User selectable upper and lower BIS limits.

    SpO2
    - GE Pulse Range: Saturation: Pulse Rate: 0 - 100% SpO2; 30 - 250 beats per minute
    - Masimo SET Range: Saturation: 30 to 100% SpO2; Pulse Rate: 25 to 240 beats per minute; Perfusion: 0.02 to 20%
    - Nellcor Range: Saturation: 1 to 100% SpO2; Pulse Rate: 20 to 250 beats per minute; Perfusion: 0.03 to 20%

    Cardiac Output (CO)
    - Range: Cardiac Output: 0.2 - 15 liters per minute; Blood Temperature: 30 - 42°C; Injectate Temperature: 0 - 30°C

    Respiration
    - Range: Respiration rate: 0 - 200 breaths per minute; Base impedance: 100 - 1000 ? at 52.6 kHz excitation frequency; Detection sensitivity: 0.4 to 10 ? variation

    Temperature
    - Temperature Range: 0°C to 45°C (32°F to 113°F)
    - Display Resolution: ±0.1°C
    - Accuracy: ±0.1°C (25°C to 45°C) independent of sensor

    Carbon Dioxide (CO2)
    - Measurement Technique: Non-dispersive infrared absorption, dual wavelength ratiometric
    - Sensor Type: Novametrix Medical Systems’ Capnostat III
    - Measurement Ranges: Pi CO2/Fi CO2: 0 to 100 mmHg/0 to 13%; Pe CO2/Fe CO2: 0 to 100 mmHg/0 to 13%; RR: 0 to 120 breaths/min