Philips Avalon CTS Rear Interface

    Philips Avalon CTS Rear Interface

    $0.00
    DESCRIPTION

    Philips Avalon CTS M1351a Features
    The Avalon Cordless Transducer System (CTS) helps transform labor and delivery, offering mothers and
    care teams the flexibility they seek by allowing comfortable, continuous fetal and maternal monitoring with
    exceptional mobility. Avalon CTS helps provide a constant and clear picture of patient status for confident
    decision-making.

    Cordless toco transducer: externally measures uterine activity
    Cordless ultrasound transducer: measures fetal movement and heart rate
    Bed identifier: matches transducers and base stations for each bed
    Base station receives transducer signals: and recharges plugged-in transducers
    Transducer plug and play with automatic screen layout, in combination with Philips fetal monitors, allows focus on patient care, not the system
    Transducer status indicators: shows how clearly system is working at all times
    Slot position indicator: helps ensure each transducer is returned to its proper home position
    Cordless ECG transducer: measures direct fetal ECG or maternal ECG
    Battery charge indicator: shows status of charge (Batteries operate at least 16 hours


    Philips Avalon CTS M1351a Specifications


    Base Dimensions
    Width: 350 mm ( 13.8 in)
    Depth: 240 mm (9.5 in)
    Height: 75 mm (3 in)
    Weight 2.5kg/5.5 lbs without transducers
    Transducer Dimensions
    Size (diameter) < 10 cm/3.94 in
    Weight < 140 g/4.8 oz
    Power
    Supply Voltages 100 VAC to 240 VAC ± 10%
    Supply Frequency Range 50 Hz to 60 Hz
    Consumption 15 VA
    Base Station
    Type of Protection Against Electrical Shock: Class I equipment
    Input Sensitivity Input Sensitivity -110 dBm @ 30dB Signal-to-Noise Ratio
    Image Rejection Image Rejection > 80dB
    Ranges
    Receiving Range (line of sight) approximately 100m/300 ft
    Antenna Input Impedance 50 O
    Water Ingress Protection Code IP X1 (protection only against vertically falling water drops)
    Monitor Interface
    Toco Output
    Accuracy ± 0,5% per 100 mmHg (not including transmitter)
    Offset ± 5 Units (not including transmitter)
    Range 0 to 4V
    Voltage Range
    US Voltage range 4mVpp to 4Vpp
    ECG Voltage range 0.1Vpp to 4Vpp
    Battery
    Type Lithium Ion
    Capacity > 16 hours (> 700mAh)
    Life > 500 charge/discharge cycles (with new battery, at 25°C/77°F)
    Transducer Storage Time
    = 1 year at 25°C/77°F (battery full)
    = 1 month at 25°C/77°F (battery empty)
    Recharging Time
    100% charged < 3h
    66% charged = 1h
    Forced discharge current approx. 45mA
    Discharge leakage current in shutdown @ Vbat = 3V, 25°C 20 µA (typical), 70 µA (max)
    RF Unit
    Nominal RF Output Power -12 dBm ± 6 dB ERP
    Carrier Frequency Range See Frequency Bands
    Minimum Frequency Band Span Per Option 10 MHz
    Channel spacing 25kHz or 12.5kHz
    General Transducer Specifications
    Shock Resistance Withstands a 1m drop to concrete surface with possible cosmetic damage
    Usability Underwater 0.5m/1.64 ft
    Water Ingress Protection Code IP 68 (0.5m/1.64 ft immersion for 5 hours)
    Environmental
    Temperature Range
    Charging 0°C to 45°C (32°F to 113°F)
    Operating 0°C to 45°C (32°F to 113°F)
    Storage (without battery) -20°C to +60°C (-4°F to 158°F)
    Storage with battery Depends on initial charge level and temperature (storage time decreases significantly at high (> 45°C/ 113°F) temperatures
    Humidity Range
    Operating 5% to 95% relative humidity @ 40°C/104°F
    Storage 5% to 85% relative humidity @ 50°C/122°F
    Altitude Range
    Operating = 3000m/9800 ft
    Storage = 15000m/49000 ft